Quantcast
Channel: data acquisition Archives - Noise & Vibration Blog
Browsing latest articles
Browse All 19 View Live

Prosig Power Units Offer New Levels Of Flexibility

The size and shape of the Prosig P8000 data acquisition systems greatly facilitates installation in locations that are small or difficult to access. Now Prosig can offer a new level...

View Article


What Are dB, Noise Floor & Dynamic Range?

Most engineers are probably familiar with or have come across the decibel or dB as a unit of measurement. Its most common use is in the field of acoustics where...

View Article


Do You Need To Measure Brake Noise?

The objective of the brake noise tests was to record the braking events of cars being driven on various types of road and classify those events according to their type...

View Article

How To Float Output Windows in DATS Acquisition V4

Nowadays it is easy to attach extra screens to most computers. It is not uncommon to have a two or even three monitor setups. Even with laptops it is fairly...

View Article

What Is The Difference Between Single Ended & Differential Inputs?

Prosig P8000 systems use differential inputs, but what are they and why are they so special? This subject is not always fully understood and, therefore, the focus of this article...

View Article


A Simple Capture, Analysis and Report (Part 1)

The first part of a series of four tutorials showing a simple setup to capture, analyze and produce a report using Prosig’s DATS software and P8000 hardware. Part 2 coming...

View Article

A Simple Capture, Analysis and Report (Part 2)

Part two of the four tutorials showing a simple setup to capture, analyze and produce a report using Prosig’s DATS software and P8000 hardware. This part deals with setting up...

View Article

Waterfall Analysis: Frequency Resolution and Smearing

When measuring noise and vibration in rotating machines, especially complex devices like automobile engines, it is very important to fully understand what is being measured and what analyses need to...

View Article


Noise & Vibration Analysis: Back To Basics

Sometimes it doesn’t hurt to revisit some of the basic building blocks that form the foundation of what we do. And so we have gathered together a few of our...

View Article


Exhaust Vibration Measurement – A Case Study

Exhaust Vibration Measurement – Customer Requirement One of Prosig’s customers needed to perform exhaust vibration measurement on some of their vehicles. They contracted Prosig to take the measurements...

View Article

Using Source Contribution Analysis to analyze complex structural dynamics issues

Using Source Contribution Analysis (SCA) and Structural Animation (STA) in the DATS software for the analysis of complex structural dynamics This post uses Source Contribution Analysis (SCA) techniques...

View Article

[Video] How To Calibrate Microphones & Accelerometers

Here are two videos on a relatively simple, but sometimes misunderstood procedure – how to calibrate microphones & accelerometers 1. How To Calibrate A Microphone 2. How To Calibrate An...

View Article

[Video] Disabling P8000 cooling fans during data capture

Justin Foster (Prosig UK) explains how to set up the DATS software to switch off the P8000’s cooling fans during data capture. This can be important to reduce noise during capture of audio data. The...

View Article


Creating calculated signals with DATS Acquisition

Case Study: What can I do if the transducer I am using has a non-linear sensitivity over its measuring range? Abstract Recently a PROSIG user wanted to measure a specific temperature parameter on a...

View Article

How to set up scheduled data captures

A video that explains how to set up the DATS Data Acquisition software to perform captures at specific, scheduled times. The post How to set up scheduled data captures appeared first on Noise &...

View Article


When should I use the ground connection on my P8000 data acquisition system?

The ground connection should be used if an issue has been observed in measured data, such as significant electricity supply (50Hz or 60Hz) distortion or significant noise. It must be attached it to a...

View Article

How to use an Analogue Channel with Tachometer Signals on the P8000

When using an analogue channel input channel of a P8000, with a tachometer sensor, is it possible to utilise the tachometer processing functions as you would if you were using a tachometer input of the...

View Article


Enabling Audio Playback in P8000 Acquisition Software

It is possible to enable audio playback to listen to audible frequencies while recording or monitoring when using a P8000 and the V4 Acquisition software. In the V4 Acquisition software you will first...

View Article
Browsing latest articles
Browse All 19 View Live